Pronto — with rainbow® technology — for noninvasive and quick spot-checking of total haemoglobin (SpHb®), oxygen saturation (SpO2), pulse rate (PR), and perfusion index (PI)
A New Solution for Haemoglobin Spot-Checking
![Nurse checking patient with Masimo Pronto](/images/rainbow/pronto/pronto_nurse.jpg)
The Pronto may provide the following benefits:
- > Facilitates timely patient assessment
- > Easy-to-use – Improves efficiency
- > Expands information available to your clinician at time of assessment
Four Simple Steps
![](/images/rainbow/pronto/pronto_front_product.jpg)
![](/images/rainbow/pronto-7/red_dot_first.jpg)
SELECT SENSOR SIZE
![measuring patient's finger to determine correct Masimo Pronto sensor size](/images/rainbow/pronto/pronto_usage_step1.jpg)
![](/images/rainbow/pronto-7/red_dot_second.jpg)
PLACE SENSOR ON FINGER
![placing noninvasive Masimo Pronto sensor on patient's finger](/images/rainbow/pronto/pronto_usage_step2.jpg)
![](/images/rainbow/pronto-7/red_dot_third.jpg)
PRESS SpHb BUTTON
![performing a spot-check with the Masimo Pronto](/images/rainbow/pronto/pronto_usage_step3.jpg)
![](/images/rainbow/pronto-7/red_dot_fourth.jpg)
OBTAIN RESULTS
![reading SpHb spot-check results with the Masimo Pronto](/images/rainbow/pronto/pronto_usage_step4.jpg)
SpHb Analytical Performance
![chart comparing SpHb from Masimo Pronto-7 versus invasive tHb measurements from a laboratory reference device](/images/rainbow/pronto/pronto_sphb_thb_chart_1.jpg)
![sphb chart 2](/images/rainbow/pronto/pronto_sphb_thb_chart_2.jpg)
In 492 comparisons of SpHb and invasive haemoglobin (tHb) measurements from a laboratory CO-Oximeter, SpHb accuracy was as follows*:
- • 0.08 g/dL bias
- • 0.96 g/dL ARMS accuracy
- • Below 12 g/dL, 99% of SpHb readings were <2 g/dL of the laboratory tHb value
- • At or above 12 g/dL, 94% of SpHb readings were <2 g/dL of the laboratory tHb value
*Masimo FDA Submission Data (Accuracy of Noninvasive Total Haemoglobin (SpHb) Measurement with Pulse CO-Oximetry). The study was performed in compliance with the requirements of IS09919:(2005) Standard.
Please note: These results were obtained following a specific protocol, in which all Directions for Use were followed and SpHb measurements were compared to validated laboratory reference measurements. Differences in results may be caused by many factors, such as those explained in Masimo’s Directions for Use. Some independent researchers have conducted their own testing and obtained similar results, while other researchers have reported larger differences when comparing SpHb measurements to laboratory measurements.
Prior to using this device, the user should read and understand the Operator’s Manual and Directions for Use. Laboratory diagnostic tests using blood samples should be conducted prior to clinical decision making to completely understand the patient’s condition. Comparisons between SpHb measurements and laboratory diagnostic hemoglobin measurements may be affected by sample type, collection technique, physiological, and other factors
For professional use. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.